rpm-ftui
Authors Y. Whulanza, DS. Widyaratih, J. Istiyanto, G. Kiswanto
Publication Name J. Engineering and Applied Sciences
Abstract

This research realised 3D constructs so called lab-on-chip as pathways to study human cell under a controlled environment. The chip is a sandwich of two microchannels with microporous membrane in between to mimic human lung system. The challenge is the fabrication of each micro part and assembles them becoming a functional micro system. Firstly, the session was preceded by realization of 20mm x 0.5mm x 0.3mm (length x width x thickness) channels. Later on, porous membrane with size of 100µm x 100µm arranged as arrays were also realised using micro milling apparatus. Eventually, the system was tested by employing 300ml/h propanol and water in each channel. The diffusion of propanol into water channel was validated by gas chromatography (GC) apparatus to validate the functionality of the system.

Publisher ARPN
ISSN 18196608
Page 2064-2067
Volume 11
Impact Factor (JCR) ---
SJR 0.2
Ranking Quartile Q3
Website http://www.arpnjournals.com/jeas/